Home › Medical grade polymers › TPU
TPU Medical Grade — Thermoplastic Polyurethane
通用塑料站收录的医疗级 TPU。脂肪族 TPU 用于血液接触与导管,聚酯型用于需要耐水解的场景,聚醚型耐候但耐水解较差。
Grades
| Grade | Manufacturer | Family | Standards |
|---|---|---|---|
| Tecoflex EG-68D-B20 | Lubrizol | 脂肪族聚醚型 TPU | USP Class VI ISO 10993 |
| Texin ISO 10993 医疗级 (三类) | Covestro (前拜耳) | 聚酯型 TPU | ISO 10993-Part 1 |
| Texin 聚酯 (三类医疗) | Covestro (前拜耳) | 聚酯型 TPU | ISO 10993-Part 1 |
- Tecoflex EG-68D-B20 (Lubrizol) — 含 20% 硫酸钡,63D 硬度。X 光可见性用于导管/介入器械定位,耐水解适合血液接触与透析。 Application: 血液接触, 透析, 牙科, 抗UV
- Texin ISO 10993 医疗级 (三类) (Covestro (前拜耳)) — ISO 10993 Part 1 覆盖的聚酯型体系。聚酯型耐油耐磨好,但耐水解弱于聚醚型,长期湿热环境需评估。 Application: 导管, 骨科, 医疗/护理用品
- Texin 聚酯 (三类医疗) (Covestro (前拜耳)) — 同为聚酯型,与上一个牌号同体系不同牌号。列出来是因为采购时通常按牌号指定。 Application: 医疗/护理用品, 骨科, 导管
Manufacturers
| Manufacturer | Notes |
|---|---|
| Lubrizol | Tecoflex 脂肪族聚醚型 TPU |
| Covestro (前拜耳) | Texin 聚酯型 TPU,德国老牌号体系 |
Reading ISO 10993
ISO 10993 is not a single certificate. It is a series, and each part answers a different toxicity question:
- Part 1 — general requirements: the framework, how to plan an evaluation, what to characterise.
- Part 3 — cytotoxicity.
- Part 4 — haemolysis (blood-contact materials).
- Part 5 — sensitisation.
- Part 6 — local irritation.
- Parts 10 / 11 — systemic toxicity (repeated dose and acute).
- Part 12 — pyrogen testing.
The scope depends entirely on the contact type and duration — a device that touches skin for a few hours is evaluated differently from an implant in permanent contact with blood. When we quote TPU, tell us the contact type and duration so we can confirm which parts apply to your application rather than quoting a blanket claim.
Standards Confirmed
| Standard | Grades | Which | What it governs |
|---|---|---|---|
| ISO 10993-Part 1 | 2 | Texin-ISO10993, Texin-Polyester | ISO 10993-1 通则:规定生物相容性评价的流程、终点选择与材料表征要求,是整套系列的总入口。 |
| ISO 10993 (Part 3/4/5/6/10/11/12) | 1 | Tecoflex EG-68D-B20 | 具体试验项:Part 3 细胞毒性、Part 4 溶血、Part 5 致敏、Part 6 刺激、Part 10-11 系统毒性、Part 12 发热。Tecoflex 该牌号覆盖全套。 |
Standards Pending Verification
We list these rather than omitting them, because you should know they exist and that we have not yet confirmed them for these grades. Claiming coverage we cannot evidence would be worse than saying nothing.
| Standard | Grades | Status | What it governs |
|---|---|---|---|
| USP Class VI pending | 0 | not yet confirmed | 该标准在本批资料里标记为待补 —— Pellethane 系列与 Estane 的认证状态尚未确认,不声称覆盖。 |
| FDA 21 CFR 177.2600 pending | 0 | not yet confirmed | 覆盖聚氨酯树脂。同为待补状态,不声称覆盖。 |
| LFGB / GB 4806.7 / EU 10/2011 pending | 0 | not yet confirmed | 食品接触体系。meta 里全部标待补(仅 Desmopan 600 提及且未完成),不声称覆盖。 |
Data Limitations
Stated up front so you can judge how far to rely on this page:
- compliance.json 里完全没有 TPU —— 无法建立带 TDS/SDS 挂载的合规页,只能建资料页
- 11467 域名限流丢了 6 个来源,lubrizol.com 被 Cloudflare 拦了 1 个
- USP Class VI / FDA 177.2600 / 食品接触三项均为待补
Frequently Asked Questions
What is TPU used for in medical devices?
通用塑料站收录的医疗级 TPU。脂肪族 TPU 用于血液接触与导管,聚酯型用于需要耐水解的场景,聚醚型耐候但耐水解较差。
Which TPU grades do you list?
3 grades from 2 manufacturers. The table above lists each grade, its manufacturer, its polymer family (GPPS / HIPS / aliphatic / polyester) and the standards it is qualified to.
Do you supply the TDS and SDS for these grades?
Not from this page — this is a reference page, not a document repository. Our document index currently covers the specialty engineering polymers. Tell us the grade designation and the document type you need and we will tell you honestly whether we can supply it. We do not list documents we do not hold.
What is the difference between aliphatic and polyester TPU?
Aliphatic TPU (the Tecoflex route) is the medical default: non-yellowing, biocompatible and hydrolysis-resistant, which is why it dominates catheters, dialysis and blood-contact applications. Polyester TPU (the Texin route) has better oil and abrasion resistance and is cheaper, but hydrolyses more readily — acceptable for dry short-term contact, less so for long-term wet service. Tell us the medium and the duration and we will say which family fits.
Why is barium sulphate added to some medical TPU?
Barium sulphate makes the part radiopaque — visible under X-ray. That matters when a catheter or introducer has to be positioned under imaging guidance. It also raises the density and slightly changes the mechanical profile, which is why it is specified per grade rather than added generically.
Which TPU standards are you not yet able to confirm?
We currently cannot confirm USP Class VI, FDA 21 CFR 177.2600, LFGB / GB 4806.7 / EU 10/2011 for the grades on this page — the source documentation for those is still being verified. We list them as pending rather than claiming coverage. What we can confirm today: ISO 10993-Part 1, ISO 10993 (Part 3/4/5/6/10/11/12).
Can you cross-reference to an alternative supplier?
Yes. For TPU the practical alternates differ by application — the list on this page covers what we have verified. Send us the grade you currently use and the application, and we will quote equivalents from other manufacturers and spell out the technical differences.
Request TPU Medical Grade
Tell us the grade designation, the application (contact type and duration), and the quantity. If you need a specific standard documented, name it — we will confirm whether we can evidence it rather than assuming. We reply within 24 hours.
Request Quote (24h reply)